A New Technique for Fast Response Measurements Using Linear Swept Sine Excitation

Authors: Struck, Christopher J.; Biering, C. Henrik

AES Convention 90 · Paper 3038 · February 1991

Abstract

Response measurements performed using Time Delay Spectrometry utilize a linearly swept sinusoidal excitation signal. Increasing the sweep rate in TDS can result in serious errors in the measured response. A new measurement technique is introduced which allows faster sweep rates to be used than with traditional TDS measurements. This technique enables the correct measurement of the complex time-selective frequency response as well as providing flexibility in the application of windowing functions.

Details

Published in
AES Convention 90
AES Convention
90
Paper number
3038
Publication date
February 6, 1991
Session subject
Loudspeaker Technology and Measurement Techniques
Affiliation
Brfiel & Kjaer, Naerum, Denmark (See document for exact affiliation information.)