Multichannel Level Alignment, Part IV: The Correlation between Physical Measures and Subjective Level Calibration

Authors: Zacharov, Nick; Bech, Søren

AES Convention 109 · Paper 5241 · September 2000

Abstract

In an effort to establish a better understanding of multichannel level alignment, a correlation and regression analysis has been performed on objective metrics and subjective data collected and subsequently reported in Parts I-III and V. This study considers subjective data acquired with nine test signals with different setups considering loudspeaker placement, directivity, reproduction bandwidth, and absolute reproduction level. Objective metrics considered include linear and weighted SPL and several loudness metrics. A constant specific loudness signal with a high-pass filter at 500 Hz was found to provide the best prediction of subjective level alignment under a wide range of practical usage situations with a wide range of metrics.:

Details

Published in
AES Convention 109
AES Convention
109
Paper number
5241
Publication date
September 6, 2000
Session subject
Multichannel Sound
Affiliation
Nokia Research Center, Tampere, Finland ; Bang & Olufsen A/S, Struer, Denmark (See document for exact affiliation information.)