S. H. Nielsen, “Auditory Distance Perception in Different Rooms,” J. Audio Eng. Soc., vol. 41, no. 10, pp. 755–770, Oct. 1993.
Nielsen SH. Auditory Distance Perception in Different Rooms. J Audio Eng Soc. 1993;41(10):755-770. Available from: https://aes.org/publications/elibrary-page/?id=6982
@article{Nielsen1993_6982,
author = {Nielsen, Søren H.},
title = {{Auditory Distance Perception in Different Rooms}},
journal = {Journal of the Audio Engineering Society},
volume = {41},
number = {10},
pages = {755--770},
year = {1993},
month = oct,
publisher = {Audio Engineering Society},
url = {https://aes.org/publications/elibrary-page/?id=6982}
}
TY - JOUR
TI - Auditory Distance Perception in Different Rooms
AU - Nielsen, Søren H.
T2 - Journal of the Audio Engineering Society
J2 - J. Audio Eng. Soc.
VL - 41
IS - 10
SP - 755
EP - 770
PY - 1993
DA - 1993/10/06
UR - https://aes.org/publications/elibrary-page/?id=6982
PB - Audio Engineering Society
LA - en
AB - A series of listening experiments was carried out to investigate how auditory distance is perceived in different rooms-an anechoic room, an IEC listening room, and a classroom. Loudspeakers playing back a voice signal were placed in the rooms. The results show that in normal rooms the sound is perceived at about the same distance as the physical distance, regardless of the playback level. In the anechoic room there is no correspondence between physical and perceived distance.
ER -