Opens in a new tab

AES E-Library

← Back to search

Convention Paper

Gap-Length Response in Magnetic Reproducers: Calculation, Measurement, and Compensations

Authors: McKnight, John G.

AES Convention 58 · Paper 1297 · November 1977

Abstract

Gap-length response S(x) is approximated within 1% by S(x) = sin pi x/pi x, where x = 1.1 lg/lambda, lg = mechanical (optical) gap length, lambda = wavelength, and x < 0.5. Alternately, the gap length is calculated from the measured null frequency fn at the speed v; then lg = 0.8795 v/f. Gap-length response compensation is required by standards, but often neglected in practical professional reproducers. Compensation is easily achieved with an RLC -peaking- circuit.

Details

Published in
AES Convention 58
AES Convention
58
Paper number
1297
Publication date
November 6, 1977
Affiliation
Magnetic Reference Laboratory, Inc., Mountain View, CA (See document for exact affiliation information.)
Type