Opens in a new tab

AES E-Library

← Back to search

Convention Paper Open Access

On the comparison of flown and ground-stacked subwoofer configurations regarding noise pollution

Authors: Mouterde, Thomas; Corteel, Etienne

AES Convention 151 · Paper 10533 · October 2021

Abstract

In addition to audience experience and hearing health concerns, noise pollution issues are increasingly considered in large scale sound reinforcement for outdoor events. Among other factors, subwoofer positioning relative to the main system influences sound pressure levels at large distances, which may be considered as noise pollution. In this paper, free field simulations are first performed showing that subwoofers positioning affects rear and side rejections but has a limited impact on noise level in front of the system. Then, the impact of wind on sound propagation at low frequencies is investigated. Simulation results show that the wind impacts more ground-stacked subwoofers than flown subwoofers, leading to higher sound levels downwind in the case of ground-stacked subwoofers.

Details

Published in
AES Convention 151
AES Convention
151
Paper number
10533
Publication date
October 6, 2021
Session subject
Transducers
Affiliation
L-Acoustics, Marcoussis, France (See document for exact affiliation information.)
Type