Opens in a new tab

AES E-Library

← Back to search

Engineering Brief

High Frequency—Ultra Audio Band Mode Voice Coil Temperature Measurement

Authors: Anazawa, Isao G.

AES Convention 142 · Paper 320 · May 2017

Abstract

As the power driving mobile devices loudspeaker increases for a better audio experience, an accurate measurement of the voice coil temperature becomes necessary in order to protect the loudspeaker from over-heating. Electrical solutions have been developed in the past to measure the temperature indirectly from the voice coil resistance using a low frequency probe tone or using main audio contents. This paper explains an ultra-audio band high frequency probe to measure the resistance. The test results show good accuracy without the known side effects that exist with current methods.

Details

Published in
AES Convention 142
AES Convention
142
Paper number
320
Publication date
May 6, 2017
Session subject
Tranducers, Education
Affiliation
NyWorks, Toronto, Ontario, Canada (See document for exact affiliation information.)
Type