Assessment of Ambisonic System Performance Using Binaural Measurements

Authors: Benjamin, Eric M.; Heller, Aaron

AES Convention 137 · Paper 9129 · October 2014

Abstract

The phenomenon described by Solvang as spectral impairment in Ambisonic reproduction is examined. The timbre of reproduced sounds is arguably the most important aspect of an audio system. In multichannel systems audio is almost always reproduced through two or more loudspeakers simultaneously. The combination of those audio signals produces variable localization, but interference between them also causes comb filtering that then causes a reduction in output at high frequencies. The present work reports on measurements, including binaural measurements, of the spectral changes encountered in Ambisonic systems. In the case where a system has more loudspeakers than the minimum required the amount of interference is increased. What is the best choice for the use of an array designed for higher-order reproduction when used to reproduce lower-order program?

Details

Published in
AES Convention 137
AES Convention
137
Paper number
9129
Publication date
October 6, 2014
Session subject
Spatial Audio
Affiliation
Surround Research, Pacifica, CA, USA; SRI International, Menlo Park, CA, USA (See document for exact affiliation information.)
Type