Influence of Different Test Room Environments on IACC as an Objective Measure of Spatial Impression or Spaciousness

Authors: Conceição, Marco; Furlong, Dermot

AES Convention 131 · Paper 8555 · October 2011

Abstract

To investigate the perceptual impression of spaciousness, a physical measure, which relates to listener spaciousness experience, was used. A variable setup was introduced that made possible the control of spaciousness in different rooms. IACC measurements were made using a frontal loudspeaker for the direct sound, with a second loudspeaker for an angled single early reflection positioned in the horizontal plane. Measurements were performed under controlled conditions in which a dummy-head measured Inter Aural Cross Correlation was captured for variable sound fields. It was possible to conclude that there is a similar trend in IACC results from the repetition of the experiments in different rooms. That is, measurement room acoustic details are not crucial to observed trends in IACC variation

Details

Published in
AES Convention 131
AES Convention
131
Paper number
8555
Publication date
October 6, 2011
Session subject
Posters: Perception
Affiliation
Trinity College Dublin, Dublin, Ireland; ESMAE-IPP, Porto, Portugal (See document for exact affiliation information.)