Abstract
In compression drivers a large membrane is coupled to a small horn throat resulting in high efficiency. For this
efficiency to be maintained to high frequencies the volume of the resulting cavity, between horn and membrane,
must be kept small. Early workers devised a phase-plug to fill most of the cavity volume and connect membrane to
horn throat with concentric annular channels of equal length to avoid destructive interference [1].
Later work, representing the cavity as a flat disc, describes a method of calculating the positions and areas of these
annular channels where they exit the cavity, giving least modal excitation, thus avoiding undesirable response
irregularities [2].
In this paper the result of applying both the equal path-length and modal approaches to a phase-plug with concentric
annular channels coupled to a cavity shaped as a flat disc is further explored. The assumption that the cavity may be
represented as a flat disc is investigated by comparing its behavior with that of an axially vibrating rigid spherical
cap radiating into a curved cavity.
It is demonstrated that channel arrangements derived for a flat disc are not optimum for use in a typical compression
driver with a curved cavity.
A new methodology for calculating the channel positions and areas giving least modal excitation is described. The
impact of the new approach will be illustrated with a practical design.