On the Quality of Some Digital Audio Equipment Measured by the High Accuracy Dynamic Distortion Measuring System

Authors: Tanabe, Hayao; Wakuri, Takashi

AES Convention 72 · Paper 1909 · October 1982

Abstract

A useful method for measuring the signal quality of digital audio equipment under operating conditions is described. An experimental system was made upon this method to measure 16-bit accuracy digital audio equipment, and the performance achieved is reported. With this measuring system, several 16-bit analog to digital and digital to analog (A/D-D/A) conversion systems and an 8:7 digital sampling frequency converter are measured. Their accuracy proved to be 13 to 14.5-bits and about 15-bits, respectively, in terms of quantizing noise level.

Details

Published in
AES Convention 72
AES Convention
72
Paper number
1909
Publication date
October 6, 1982
Session subject
Audio Tests and Measurements
Affiliation
Technical Research Laboratories of NHK, Tokyo, Japan (See document for exact affiliation information.)