C. P. Boner and C. R. Boner, “Equalization of the Sound System in the Harris County Domed Stadium,” in Proc. AES Convention 17, Oct. 1965, pp. 380:1-6. [Online]. Available: https://aes.org/publications/elibrary-page/?id=1060
Boner CP, Boner CR. Equalization of the Sound System in the Harris County Domed Stadium. In: AES Convention 17. Audio Engineering Society; 1965.pp. 380:1-6. Available from: https://aes.org/publications/elibrary-page/?id=1060
@inproceedings{Boner1965_1060,
author = {Boner, C. Paul and Boner, C. R.},
title = {{Equalization of the Sound System in the Harris County Domed Stadium}},
booktitle = {AES Convention 17},
pages = {380:1-6},
url = {https://aes.org/publications/elibrary-page/?id=1060},
year = {1965},
month = oct,
publisher = {Audio Engineering Society}
}
TY - CPAPER
TI - Equalization of the Sound System in the Harris County Domed Stadium
AU - Boner, C. Paul
AU - Boner, C. R.
T2 - AES Convention 17
SP - 1
EP - 6
M1 - Paper 380
PY - 1965
DA - 1965/10/06
UR - https://aes.org/publications/elibrary-page/?id=1060
PB - Audio Engineering Society
LA - en
AB - Following the completion of the installation of the sound system in the Harris County Domed Stadium, broad-band equalization procedures were begun in order to bring the response in the seating areas to the specifications. Principal requirements covered acoustic frequency response and seat-to-seat variations in sound pressure level. the initial equalization consisted primarily of bringing up the upper high-frequency response, reducing response between 500 cps and 900 cps, and setting down the region above the 500 cps crossover by 4 dB. RLC equalization was performed in order to accomplish this.