Opens in a new tab

AES E-Library

← Back to search

Journal Article

Design Criteria for Headphones

Authors: Møller, Henrik; Jensen, Clemen Boje; Hammershøi, Dorte; Sørensen, Michael Friis

Journal of the Audio Engineering Society · Volume 43 · Issue 4 · pp. 218–232 · April 1995

Abstract

An alternative procedure is proposed for measuring headphone performance on human ears. Psychoacoustic procedures are replaced with the measurement of sound pressure at the input to the human ear canal. Furthermore, the exposure of each subject to a reference sound field is replaced by prior knowledge ofa desired frequency response. Design goals are given for free-field- and diffuse-field-calibrated headphones, and for measurements at the open and blocked ear canal. The new method avoids the uncertainty from a psychometric procedure, and it allows difuse-field calibration even at pure tones and narrow frequency bands. Also the extra variance from a physical diffuse sound field is avoided.

Details

Publication
Journal of the Audio Engineering Society
Volume
43
Issue
4
Pages
218–232
Publication date
April 6, 1995
Affiliation
Acoustics Laboratory, Aalborg University, Aalborg, Denmark (See document for exact affiliation information.)
Type