Some Studies on the Reduction of Head Wear Caused by Magnetic Tapes and a Test Device for Measuring the Relative Wear on a Simulated Head

Authors: Tufano, Albert L.; Flower, Jr., Guiles

Journal of the Audio Engineering Society · Volume 10 · Issue 1 · pp. 60–63 · January 1962

Abstract

This paper describes the results of some studies to determine the effects of various surface treatments to decrease head wear caused by contact with magnetic tape. A test device for simulating head wear and a means of measuring the relative head wear is described. The possible effects on output at low and high frequencies and the noise level were investigated.