Opens in a new tab

AES E-Library

← Back to search

Convention Paper

A New Sound Intensity Probe: Comparison to the Brüel & Kjaer P-P Probe

Authors: Druyvesteyn, W. F.; de Bree, H. E.

AES Convention 104 · Paper 4651 · May 1998

Abstract

A new intensity probe consisting of a pressure (p) and a particle velocity (v) sensor has been designed and tested. The experimental results are compared with the existing Brüel and Kjaer probe. The Microflown v-sensor consists of two wires acting as both heater and sensor. The results are that the new p-v probe is as good as the B & K p-p probe.

Details

Published in
AES Convention 104
AES Convention
104
Paper number
4651
Publication date
May 6, 1998
Session subject
Measurement and Instrumentation
Affiliation
Philips Research Labs., Eindhoven, The Netherlands ; MESA Research Institute University of Twente Enschede, The Netherlands (See document for exact affiliation information.)
Type
Convention Paper