Tape Flux Measurement Revisited

Authors: McKnight, John G.; Cortez, Benito E.; McKnight, Jeffrey A.

AES Convention 105 · Paper 4802 · September 1998

Abstract

Analog magnetic recording standards specify recorded signal magnitude in terms of short-circuit flux per unit track width, called fluxivity. Two flux measurement methods are standardized: a direct ac method using a high-efficiency head (AES7/ANSI Standard S4.6); and a transfer-to-dc method using a fluxmeter (German Standard DIN 45 520).: A transfer-to-dc measurement made in the 1950s is used to calibrate the fluxivity of German calibration tapes. When these tapes are measured by the direct ac method, the fluxivity is 10% less than the stated value. Thus the 1950s German transfer-to-dc measurement was 10% more sensitive than the direct ac measurement.: A new comparison of the two measurement methods shows that they actually have the same sensitivity within an experimental error of about 0.5%. Thus we conclude that the German measurement in the 1950s must have had a 10% error, and that the fluxivity on all of the calibration tapes based on the old German measurement is 10% less than the stated value tapes identified as 320 nWb/m are actually 288 nWb/m.

Details

Published in
AES Convention 105
AES Convention
105
Paper number
4802
Publication date
September 6, 1998
Session subject
Instrumentation and Measurement
Affiliation
Magnetic Reference Laboratory, Mountain View, CA (See document for exact affiliation information.)