Signal-To-Noise Problems and A New Equalization for Magnetic Recording of Music

Authors: McKnight, John G.

Journal of the Audio Engineering Society · Volume 7 · Issue 1 · pp. 5–12 · January 1959

Abstract

Measuring procedures and specifications currently used in the sound recording industry are inadequate. A weighting network should be used to objective noise measurement work to evaluate developments toward a lower noise system. We know that the ear is most sensitive in the 1 to 6 kc region, and it is possible to use preemphasis in this region. Better signal-to-noise ratio may be obtained in 15 ips magnetic recorders by utilizing fully their present capabilities. Subjective listening tests show that a system with the 1 to 6 kc region pre-emphasized (the AME curve) is some 7 db quieter than the same system using the NAB curve, but does not show any audible increase in distortion.

Details

Publication
Journal of the Audio Engineering Society
Volume
7
Issue
1
Pages
5–12
Publication date
January 6, 1959
Affiliation
Ampex Corporation, Redwood City, CA (See document for exact affiliation information.)
Type