E.-J. Völker, “Room Modes and Deep Tone Reproduction in Control Rooms for Music Monitoring,” in Proc. AES Convention 80, Mar. 1986, Paper 2354. [Online]. Available: https://aes.org/publications/elibrary-page/?id=5076
Völker EJ. Room Modes and Deep Tone Reproduction in Control Rooms for Music Monitoring. In: AES Convention 80. Audio Engineering Society; 1986. Paper 2354. Available from: https://aes.org/publications/elibrary-page/?id=5076
@inproceedings{Volker1986_5076,
author = {Völker, Ernst-Joachim},
title = {{Room Modes and Deep Tone Reproduction in Control Rooms for Music Monitoring}},
booktitle = {AES Convention 80},
note = {Paper 2354},
year = {1986},
month = mar,
publisher = {Audio Engineering Society},
url = {https://aes.org/publications/elibrary-page/?id=5076}
}
TY - CPAPER
TI - Room Modes and Deep Tone Reproduction in Control Rooms for Music Monitoring
AU - Völker, Ernst-Joachim
T2 - AES Convention 80
M1 - Paper 2354
PY - 1986
DA - 1986/03/06
UR - https://aes.org/publications/elibrary-page/?id=5076
PB - Audio Engineering Society
LA - en
AB - Control rooms for music monitoring sometimes suffer from irregularities in reproduction of deep tones under 100 Hz. These originate from Eigentons or room modes with their standing waves and landscape of modes. Measurements in control rooms have been made and have shown that these modes can be influenced by the shape of the room, reflectors in corners or on the wall or tuned resonators with high absorption. It is of advantage to use variable absorbers with a set resonance frequency which can be mounted in an optimal position. Measurements and provisions will be discussed.
ER -