Opens in a new tab

AES E-Library

← Back to search

Journal Article

Measuring Loudspeaker Constants by a Transient Method

Authors: Jacobsen, Oluf

Journal of the Audio Engineering Society · Volume 30 · Issue 3 · pp. 112–116 · March 1982

Abstract

The voltage response at the input terminals of a loudspeaker and the sound pressure response at the center of the diaphragm to an input step current are recorded in the form of an oscillogram or a YT plot. From this the elements of the equivalent electrical network and the force factor can be determined, and the derived parameters calculated. The method is well suited for on-line electronic data processing which would make the measurement a split-second matter. The force factor can, alternatively, be determined from a steady-state measurement of the input voltage and the sound pressure. Results from the method described and from a conventional steady-state method are compared. They differ by 5% at most, except for the values for the mechanical resistance, which are all higher for the transient method, by 10% on the average.

Details

Publication
Journal of the Audio Engineering Society
Volume
30
Issue
3
Pages
112–116
Publication date
March 6, 1982
Affiliation
Aarhus Teknikum, Aarhus, Denmark (See document for exact affiliation information.)
Type