M. C. Killion, “Vibration Sensitivity Measurements on Subminiature Condenser Microphones,” J. Audio Eng. Soc., vol. 23, no. 2, pp. 123–127, Mar. 1975.
Killion MC. Vibration Sensitivity Measurements on Subminiature Condenser Microphones. J Audio Eng Soc. 1975;23(2):123-127. Available from: https://aes.org/publications/elibrary-page/?id=2708
@article{Killion1975_2708,
author = {Killion, Mead C.},
title = {{Vibration Sensitivity Measurements on Subminiature Condenser Microphones}},
journal = {Journal of the Audio Engineering Society},
volume = {23},
number = {2},
pages = {123--127},
year = {1975},
month = mar,
publisher = {Audio Engineering Society},
url = {https://aes.org/publications/elibrary-page/?id=2708}
}
TY - JOUR
TI - Vibration Sensitivity Measurements on Subminiature Condenser Microphones
AU - Killion, Mead C.
T2 - Journal of the Audio Engineering Society
J2 - J. Audio Eng. Soc.
VL - 23
IS - 2
SP - 123
EP - 127
PY - 1975
DA - 1975/03/06
UR - https://aes.org/publications/elibrary-page/?id=2708
PB - Audio Engineering Society
LA - en
AB - A recently introduced series of subminiature electret-condenser microphones has brought to light an interesting problem: Their vibration sensitivity is so low that an accurate measurement becomes difficult. Not only must the microphone be isolated from the sound pressure generated by the vibration driver, but simply vibrating the microphone creates a -radiation pressure- which must be taken into account. Measurement techniques are described which permit the accurate measurement of vibration sensitivity even when the vibration sensitivity of the microphone is extremely low.