I. G. Anazawa, “High Frequency—Ultra Audio Band Mode Voice Coil Temperature Measurement,” in Proc. AES Convention 142, May 2017, pp. 320:1-. [Online]. Available: https://aes.org/publications/elibrary-page/?id=18695
Anazawa IG. High Frequency—Ultra Audio Band Mode Voice Coil Temperature Measurement. In: AES Convention 142. Audio Engineering Society; 2017.pp. 320:1-. Available from: https://aes.org/publications/elibrary-page/?id=18695
@inproceedings{Anazawa2017_18695,
author = {Anazawa, Isao G.},
title = {{High Frequency—Ultra Audio Band Mode Voice Coil Temperature Measurement}},
booktitle = {AES Convention 142},
pages = {320:1-},
year = {2017},
month = may,
publisher = {Audio Engineering Society},
url = {https://aes.org/publications/elibrary-page/?id=18695}
}
TY - CPAPER
TI - High Frequency—Ultra Audio Band Mode Voice Coil Temperature Measurement
AU - Anazawa, Isao G.
T2 - AES Convention 142
SP - 1
M1 - Paper 320
PY - 2017
DA - 2017/05/06
UR - https://aes.org/publications/elibrary-page/?id=18695
PB - Audio Engineering Society
LA - en
AB - As the power driving mobile devices loudspeaker increases for a better audio experience, an accurate measurement of the voice coil temperature becomes necessary in order to protect the loudspeaker from over-heating. Electrical solutions have been developed in the past to measure the temperature indirectly from the voice coil resistance using a low frequency probe tone or using main audio contents. This paper explains an ultra-audio band high frequency probe to measure the resistance. The test results show good accuracy without the known side effects that exist with current methods.