Opens in a new tab

AES E-Library

← Back to search

Convention Paper

Magnetic Recording Tape: The Influence of the Magnetic Coating Thickness Upon Signal Parameters

Authors: Manly, Jr., William A.

AES Convention 35 · Paper 614 · October 1968

Abstract

An empirical study has been made on the dependence of bias, sensitivity, response, output at saturation, distortion, print through, and noise, on the thickness of the magnetic coating. It is shown that for audio and instrumentation (analog) tapes, where the record head gap is sufficiently long, the greatest percentage of the variations observed in measured parameters is due to the variation in the thickness of the magnetic coatings. In some cases, the customer requirements are such that specification limits require resolutions in coating thickness measurements which are almost unobtainable.

Details

Published in
AES Convention 35
AES Convention
35
Paper number
614
Publication date
October 6, 1968
Affiliation
Ampex Corporation, Magnetic Tape Laboratory, Redwood City, CA (See document for exact affiliation information.)
Type