Opens in a new tab

AES E-Library

← Back to search

Convention Paper

Refinements in the Impulse Testing of Loudspeakers

Authors: Fincham, Laurie R.

AES Convention 74 · Paper 2055 · October 1983

Abstract

The evaluation of a loudspeaker's transfer function or frequency response (amplitude and phase) via digital processing of its measured impulse response is now an established technique. During ten years experience with the method, many practical problems of measuring accuracy were encountered. This paper will discuss the causes and suggested remedies for reducing measuring errors, particularly at low frequencies, due to drive unit nonlinearities, signal averaging in the presence of both random and synchronous background noise, and DC offset in the A/D converter. In addition, a novel method for accurately determining the free field response of a loudspeaker system down to very low frequencies will be presented. It will be shown that it is possible using this method to estimate a loudspeaker's frequency response to an accuracy of better than 1 dB down to 20 Hz using only 10mS of its impulse response measured in a non-anechoic environment.

Details

Published in
AES Convention 74
AES Convention
74
Paper number
2055
Publication date
October 6, 1983
Session subject
Loudspeakers: Transducers and Low-Frequency System Alignments
Affiliation
KEF Electronics Limited, Tovil, Maidstone, Kent, England (See document for exact affiliation information.)
Type